Here in this post I explain how to reset the error code sc541, sc542, sc543, sc545 and sc547 on your Ricoh SP C250sf, C252SF, and C261SF printer. Although the printer is physically fine, it will not be ready until the previous error condition is cleared. We are sharing a few methods to fix this error, so check them one by one until it gets solved.
Ricoh SP C250SF error code sc542 solution
![]() |
how to clear service call sc542 Ricoh sp c250sf |
Here in this post, I explain how to reset the error code sc541, sc542, sc543, sc545 and sc547 on your Ricoh SP C250sf, C252SF, and C261SF printer. Although the printer is physically fine, it will not be ready until the previous error condition is cleared. We are sharing a few methods to fix this error, so check them one by one until it gets solved.
Meaning of the sc542 Error Code:
Ricoh SP c250sf Error code SC542 indicates a fuser temperature problem. Fusing Temperature The inside fusing does not reach standby temperatures 125 seconds after turning on the main power switch. Once the error is reached, the printer is toasting until the error is automatically cleared from the display.
How to fix the sc542 error code:
You can fix it in some of the simplest processes. Follow the steps below:
- Pressing the “C” button on the panel.
- Then press “1, 0, 7” on the keypad
- Press the “start” button. (you get a new screen “Maintenance Mode”)
- Search to “Engine maintenance” then press “ok”.
- Search “Fuser SC Reset” then press ok button
- You can see the new screen Are you sure to execute, press the Execute below button.
- After turning off the main power switch, wait 10 seconds and fire the machine back up, now reset your error
If that does not work, you need to check these all
I hope this was helpful, don’t forget to share it via any of the share buttons on this page are highly welcomed as well.
- Please verify that the thermistors are correct and installed correctly.
- Check the thermostats and fusing lamps for the open circuit.
- Poor fusing unit connector.
- The power supply board defective.
After you replace the part, then you have to reset the machine in service mode.