Sharp C4-02 error code means is for the PTC unit (Primary Transfer Charge unit) heater open trouble. You can disable it through the program to use the machine
Sharp MX-4101n error code C4-02 solutions
![]() |
How to solve C4-02 error in sharp mx-3110n |
Meaning of the C4-02 error code:
Sharp C4-02 error code means is for the PTC unit (Primary Transfer Charge unit) heater open trouble. You can disable it through the program to use the machine, but you must replace the PTC unit if the Trouble Code is continuously displayed.
You have to reset fuser errors.
- Press the key on control panel > “#, *, c, *”
- You should be in service mode now. Type in number “14” press start.
- Then you want type subcode 01 press start.
- Then you can select ok. Then switch off the machine and turn the power back ON at the power socket and the code should reset. The machine will process for 2 minutes.
Although the error code is shown again. You must replace the PTC unit. You can disable it through the program to use the machine. Adjust the settings to ignore the PTC issue and the machine can be temporarily run. Set engine soft SW8-3 to "1" in SIM55-1. This setting disables PTC output, heater control, and error detection. After the repair is complete, set the engine soft SW8-3 to "0" on the SIM55-1.
I hope this was helpful, don’t forget to share it via any of the share buttons on this page are highly welcomed as well.
I would like to give my gratitude to Wizard James Services because this site is the only one where there is nothing superfluous going on, they were completely honest and transparent all the way through. They said they could crack my wallet, it took them 4 hours and they took their 20% and left me the rest, Job well done. His contact: wizardjamesrecovery@usa.com or WhatsApp: +1 (863) 254-2842