canon ir 3235 error code e00007 solution

Clear Error E000007
Clear Error E000007-0000 code for Canon IR3235/IR3025
Are you getting the status as E0007 no signal on your Canon copier? These instructions describe the error code E0007 solution for a Canon IR3235, IR3025, ir3530, ir3570, ir3030, and ir4570 copier machine. This should solve your problem. This introduction will help you troubleshoot some common error messages related to Error Code E0007, E0003 that you may receive. It is any of the ImageRunner models. If that is the case consider the following.

The maintenance sign means that the copier needs to be well serviced and checked if something is to be replaced. Consumables such as drum, blade, fuser rollers, and developers are changed at such times. If you are sure that you have replaced the correct part or nothing is to be replaced, then you can proceed to clear the sign.

Meaning of E000007 the Error Code

The Problem with fixing the film rotation issue, while the fixing motor is rotating, the marker the signal is not detected for 6 sec with the reading of the main thermistor indicating 100 deg C or more. You will need to replace the upper film unit or the whole fuser unit to repair the problem.   Reset the condition in service mode. It could be a fixing film, pressure roller bush or fixing film sensor. After U replaces the part, below is the procedure to clear these errors.

How to Fix the Error Code?

Do not worry if you get this error, in some rare cases, you can solve it by a very simple process. Follow the steps below:
  1. Check the fuser film: You have to remove the Fuser unit (FG6-6040-000) from the machine and manually rotate the gear. Either it’s torn or the little white patch at the end of the film is dirty. It may be worn-out. Simply change the fuser film with the new one. The code will remove.
  2. Apply the grease or fuser oil: You can check the film is rotating or not rotating.  If not rotating grease inside the film may be dry. , remove all the old grease and apply new grease or fuser oil lightly. And now try to rotate.
  3. Check the pressure roller: if not rotate properly the fuser Film then check pressure roller, rubber ring, and bush. It may be worn-out. Replace the cleaning roller of the pressure roller. If you have over 300 000 copies change the press roller, bushings, and rubber ring. Change the cleaning roller or cleaning every 10-15K copy’s to prevent premature fixing problems.
  4. Check the fixing film sensor is faulty:  This could be a dirty sensor. Or Check the connector of the fixing film.

  


After you replace the part, you have to reset the machine in service mode COPIER

Note:

If you have over the 500000 copy’s the best solution is to replace the whole fixing unit, an A little expensive but worded.

I would use only the original grease. Grease and oil are very different. Trying to save money can end up costing more time and money. Play it safe. Precision Roller has fixing film grease in a syringe that will do 50 sleeves for less than $40. Part# S4800.